Showing results: 211 - 225 of 305 items found.
-
836 Series -
Leco Corp.
The ONH836 Oxygen/Nitrogen/Hydrogen Elemental Analyzer is designed for wide-range measurement of oxygen, nitrogen, and hydrogen content of inorganic materials, ferrous and nonferrous alloys, and refractory materials using the inert gas fusion technique.
-
CEMS-2000B FT -
Focused Photonics Inc.
CEMS-2000 B FT system uses direct thermal wet extraction method based on FTIR gas analysis technology, the system mainly has three major components: sampling pre-process-ing system, FTIR gas analyzer,and data acquisition and processing unit. The system can simultaneously monitor multiple groups of components in flue gas such as SO, NO, NO2, NOx, NH3, HCL, HF, O2, CO, CO2, CH4, H2O, etc. It is especially suitable for waste incineration.
-
MKS Instruments
Our process monitors are innovative in-situ process monitoring instruments that are fully integrated, application-specific packages, including component residual gas analyzers (RGAs), analytical equipment, and control software. Process mass spectrometers are used in varied applications, including; Semiconductor, Thin Film (CVD, Etch, PVD and degas), pharmaceutical lyophylization and bulk gas purity monitoring.
-
Jinan Saicheng Instrument
The headspace gas analyzer adopts a professional structure design and is equipped with a high-precision sensor, which can accurately and conveniently determine the content and mixing ratio of O2 and CO2 in hollow packaging containers such as sealed packaging bags, bottles and cans. The equipment is used for headspace gas analysis and detection of various sealed packaging bags, packaging containers, vials, ampoules and other products.
-
ZNV-7 -
HORIBA, Ltd.
HORIBA Europe’s Zero Gas Generator ZNV-7 has been developed to check the zero point and dilute the span gas sources in order to carry out the calibration of ambient air monitoring systems. The increasing sensitivity of ambient air analyzers is required by strict official guidelines, which demands pure and dry air in a sufficient quantity at constant pressure.
-
4100 -
Bacharach, Inc.
The Neutronics 4100 Trace Oxygen Analyzer is a compact analyzer for trace oxygen gas measurement and process control applications. With a measurement range of ppb (parts per billion) to 100% oxygen, this analyzer features a remote sensor module with the Neutronics rapid response zirconium oxide sensor. With extremely high accuracy, rapid response, and a long-expected service life, this analyzer is a low-maintenance solution that delivers reliable performance for critical applications that require oxygen contaminant monitoring in the ppb range.
-
Micromeritis
The new BreakThrough Analyzer (BTA) is a flexible gas delivery and management system for the precise characterization of adsorbent performance under process-relevant conditions. It delivers reliable adsorption data for gas/vapor mixtures using a flow-through system.
-
LT GasAnalyzer -
LT Gasetechnik
Highly performant analyzer for measuring the concentration of technical gases based on a thermal conductivity sensor, an infrared sensor a para magnetic sensor or combinations of these sensors. Sensors are precise, robust and have a low cross-sensitivity. Extractive online measurement of the concentration of flammable or non-flammable gas components in gas mixtures. Can measure trace oxygen (O2) levels in the parts per million (ppm) range.
-
PPM100 -
Stanford Research Systems, Inc.
The PPM100 is a stand-alone controller/monitor for SRS residual gas analyzers. It measures partial pressures from SRS RGAs and total pressure from up to four capacitance manometers. Graphical output is available on a touchscreen LCD display.
-
Thermo Fisher Scientific Inc.
Ambient Gas Monitoring: We offer a variety of analyzers for the ambient monitoring of the criteria pollutant gases, including CO, NOX, SO2, and others such as CH4 and CO2. Source Gas Monitoring (Emissions Monitoring): Experience reliable measurement in your process for emissions compliance every time.Ambient Particulate Monitoring: Experience our monitoring technology and gain the power to do more than just inform.Emissions Calibrators: For continuous monitoring of mercury in exhaust stacks, waste incinerators, and cement kilns, or multi-gas models to control the calibration of gas concentrations.
-
Teledyne Advanced Pollution Instrumentation
Teledyne API's Carbon compound analyzers utilize Gas Filter Correlation combined with reliable NDIR (non-dispersed infrared) technology to produce very stable and accurate gas measurements. All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. All of our instruments are designed meet the rigorous demands of ambient air quality, stack, or industrial process gas monitoring.
-
3100 Percent Oxygen -
Bacharach, Inc.
The Neutronics 3100 Percent Oxygen Analyzer is a compact analyzer that features the Neutronics rapid response zirconium oxide sensor and a measurement range of 0.1 ppm to 100% oxygen. With its extremely fast response time and high accuracy, the Model 3100 delivers reliable performance for a wide variety of oxygen gas measurement and critical process control applications.
-
CI-IN19 -
Shanghai ChangAi Electronic Science & Technology Co.,Ltd
CI-IN19 humidity analyzer uses vast-contrast humidity sensor as testing unit. It’s an intelligent analyzer at the core of micro-processor and made of detector part & display part. It’s use to measure the relative humidity in air and vapor mixed gas between o to 200℃. - See more at: http://en.ci-ele.com/fb01357d-94e6-2795-f3d2-ea8d5b3a3d31/f7847efb-fece-c4be-5376-3bd0f9a8eeba.shtml#sthash.KCqpmhCp.dpuf
-
Model N500 -
Teledyne Advanced Pollution Instrumentation
The Model N500 CAPS NOx analyzer uses superior Cavity Attenuated Phase Shift (CAPS) Spectroscopy to measure True NO2, NOx, and NO gases. The instrument combines direct NO2 measurements with highly efficient gas phase titration (GPT) to convert and measure the NO gas component. An automatic baseline reference cycle accounts and compensates for any potential baseline drift due to varying environmental conditions.
-
FGA-1000 -
Atom Instrument
ATOM Instrument offers the most versatile total sulfur analyzers available. The ATOM FGA-1000 is an online process analyzer utilizing patented Excimer UV Fluorescence (EUVF) Technology to measure Total Sulfur in a variety of applications such as monitoring refinery flare gas and subsequent sulfur dioxide (SO2) emissions as mandated by the EPA Rule 40 CFR 60, Subpart Ja.